Wilo Economy MHI

Non-self priming horizontal multistage transfer pumps.

 

 

 

 

 

 

 

 

 

 

Your advantages
IE3 IEC three-phase AC motor (≥ 0.75 kW)
All parts that come in contact with the fluid are made of stainless steel 1.4301 (AISI 304) or 1.4404 (AISI 316L)
Space-saving, compact design
Drinking water approval (ACS, KTW, WRAS) for all components in contact with the fluid (EPDM version)

Construction
Non self-priming multistage pump

Application
Water supply and pressure boosting
Irrigation
Heating
In industrial systems (foodstuff industry, renewable energies, shipbuilding): Cooling and washing system

Equipment/function
Stainless steel in monobloc design
Threaded connection
Single-phase or three-phase AC motor
Single-phase AC motor equipped with built-in thermal motor protection (with automatic restart)

Scope of delivery
Pump
Installation and operating instructions

Technical data
Mains connection 1~230 V (±10 %), 50 Hz or optionally 220 V (±10 %), 60 Hz
Mains connection: 3~230 V (±10 %), 50 Hz (Δ) or optionally 265 V (±10 %), 60 Hz (Δ), 400 V (±10 %), 50 Hz (Y) or optionally 460 V (±10 %), 60 Hz (Y); same motor also: 3~220 V (±10 %), 60 Hz (Δ), 380 V (±10 %), 60 Hz (Y);
Fluid temperature of -15 to +110 °C
Max. operating pressure 10 bar
Max. inlet pressure of 6 bar
Protection class 1~: IPX4; 3~: IP54
Nominal diameters of pipe connections: Rp 1, Rp 1 ¼ or Rp 1 ½, depending on type

Materials
Impellers, stage chambers and pump housing made of 1.4301/1.4404 stainless steel
Shaft 1.43.01 or 1.4404 stainless steel
Seal EPDM (EP 851) / FKM (Viton)
EPDM version of mechanical seal: B carbon/silicon carbide, FKM version: Silicon carbide/B-carbon
Bearing tungsten carbide/aluminium oxide
Pump support foot aluminium

Wilo Economy MHI

Non-self priming horizontal multistage transfer pumps.

 

 

 

 

 

 

 

 

 

 

Your advantages
IE3 IEC three-phase AC motor (≥ 0.75 kW)
All parts that come in contact with the fluid are made of stainless steel 1.4301 (AISI 304) or 1.4404 (AISI 316L)
Space-saving, compact design
Drinking water approval (ACS, KTW, WRAS) for all components in contact with the fluid (EPDM version)

Construction
Non self-priming multistage pump

Application
Water supply and pressure boosting
Irrigation
Heating
In industrial systems (foodstuff industry, renewable energies, shipbuilding): Cooling and washing system

Equipment/function
Stainless steel in monobloc design
Threaded connection
Single-phase or three-phase AC motor
Single-phase AC motor equipped with built-in thermal motor protection (with automatic restart)

Scope of delivery
Pump
Installation and operating instructions

Technical data
Mains connection 1~230 V (±10 %), 50 Hz or optionally 220 V (±10 %), 60 Hz
Mains connection: 3~230 V (±10 %), 50 Hz (Δ) or optionally 265 V (±10 %), 60 Hz (Δ), 400 V (±10 %), 50 Hz (Y) or optionally 460 V (±10 %), 60 Hz (Y); same motor also: 3~220 V (±10 %), 60 Hz (Δ), 380 V (±10 %), 60 Hz (Y);
Fluid temperature of -15 to +110 °C
Max. operating pressure 10 bar
Max. inlet pressure of 6 bar
Protection class 1~: IPX4; 3~: IP54
Nominal diameters of pipe connections: Rp 1, Rp 1 ¼ or Rp 1 ½, depending on type

Materials
Impellers, stage chambers and pump housing made of 1.4301/1.4404 stainless steel
Shaft 1.43.01 or 1.4404 stainless steel
Seal EPDM (EP 851) / FKM (Viton)
EPDM version of mechanical seal: B carbon/silicon carbide, FKM version: Silicon carbide/B-carbon
Bearing tungsten carbide/aluminium oxide
Pump support foot aluminium

Wilo Economy MHIL

Non-self priming horizontal multistage pump.

 

 

 

 

 

 

 

 

 

 

Your advantages
IE3 IEC three-phase AC motor (≥ 0.75 kW)
Impellers and stage housing made of stainless steel
Pump housing made of EN-GJL-250 cast iron, KTL coating
Single-phase and three-phase versions available

Construction
Non-self-priming, multistage pump

Application
Water supply and pressure boosting
Irrigation
Heating
In industrial systems (foodstuff industry, renewable energies): Cooling and washing system

Equipment/function
Pump in block design
Threaded connection
Single-phase or three-phase AC motor
Single-phase motor with integrated thermal motor protection

Scope of delivery
Pump
Installation and operating instructions

Technical data
Mains connection 1~230 V (±10 %), 50 Hz or optionally 220 V (±10 %), 60 Hz
Mains connection 3~230 V (±10 %), 50 Hz (Δ) or optionally 220 V (±10 %), 50 Hz (Δ), 400 V (±10 %), 50 Hz (Y) or optionally 460 V (±10 %), 60 Hz (Y)
Fluid temperature -15 to +90 °C
Max. operating pressure 10 bar
Max. inlet pressure 6 bar
Protection class 1~: IPX4; 3~: IP54
Nominal diameters of pipe connections on pressure side: Rp 1 or Rp 1 ¼, depending on type
Nominal diameters of pipe connections on suction side Rp 1, Rp 1 ¼ or Rp 1 ½, depending on type

Materials
Impellers of stainless steel 1.4301
Stage chambers made of 1.4301 stainless steel
Shaft of stainless steel 1.4301 (AISI 304) or 1.4057 (AISI 431 L)
EPDM seal
Housing cover EN-GJL-250 (KTL-coated)
Lower housing section EN-GJL-250 (KTL-coated)
Mechanical seal made of SiC/carbon
Bearing of tungsten carbide
Pump support foot EN-GJL-250 (KTL-coated)

Wilo Economy MHIL

Non-self priming horizontal multistage pump.

 

 

 

 

 

 

 

 

 

 

Your advantages
IE3 IEC three-phase AC motor (≥ 0.75 kW)
Impellers and stage housing made of stainless steel
Pump housing made of EN-GJL-250 cast iron, KTL coating
Single-phase and three-phase versions available

Construction
Non-self-priming, multistage pump

Application
Water supply and pressure boosting
Irrigation
Heating
In industrial systems (foodstuff industry, renewable energies): Cooling and washing system

Equipment/function
Pump in block design
Threaded connection
Single-phase or three-phase AC motor
Single-phase motor with integrated thermal motor protection

Scope of delivery
Pump
Installation and operating instructions

Technical data
Mains connection 1~230 V (±10 %), 50 Hz or optionally 220 V (±10 %), 60 Hz
Mains connection 3~230 V (±10 %), 50 Hz (Δ) or optionally 220 V (±10 %), 50 Hz (Δ), 400 V (±10 %), 50 Hz (Y) or optionally 460 V (±10 %), 60 Hz (Y)
Fluid temperature -15 to +90 °C
Max. operating pressure 10 bar
Max. inlet pressure 6 bar
Protection class 1~: IPX4; 3~: IP54
Nominal diameters of pipe connections on pressure side: Rp 1 or Rp 1 ¼, depending on type
Nominal diameters of pipe connections on suction side Rp 1, Rp 1 ¼ or Rp 1 ½, depending on type

Materials
Impellers of stainless steel 1.4301
Stage chambers made of 1.4301 stainless steel
Shaft of stainless steel 1.4301 (AISI 304) or 1.4057 (AISI 431 L)
EPDM seal
Housing cover EN-GJL-250 (KTL-coated)
Lower housing section EN-GJL-250 (KTL-coated)
Mechanical seal made of SiC/carbon
Bearing of tungsten carbide
Pump support foot EN-GJL-250 (KTL-coated)

Wilo Economy MHIL

Non-self priming horizontal multistage pump.

 

 

 

 

 

 

 

 

 

 

Your advantages
IE3 IEC three-phase AC motor (≥ 0.75 kW)
Impellers and stage housing made of stainless steel
Pump housing made of EN-GJL-250 cast iron, KTL coating
Single-phase and three-phase versions available

Construction
Non-self-priming, multistage pump

Application
Water supply and pressure boosting
Irrigation
Heating
In industrial systems (foodstuff industry, renewable energies): Cooling and washing system

Equipment/function
Pump in block design
Threaded connection
Single-phase or three-phase AC motor
Single-phase motor with integrated thermal motor protection

Scope of delivery
Pump
Installation and operating instructions

Technical data
Mains connection 1~230 V (±10 %), 50 Hz or optionally 220 V (±10 %), 60 Hz
Mains connection 3~230 V (±10 %), 50 Hz (Δ) or optionally 220 V (±10 %), 50 Hz (Δ), 400 V (±10 %), 50 Hz (Y) or optionally 460 V (±10 %), 60 Hz (Y)
Fluid temperature -15 to +90 °C
Max. operating pressure 10 bar
Max. inlet pressure 6 bar
Protection class 1~: IPX4; 3~: IP54
Nominal diameters of pipe connections on pressure side: Rp 1 or Rp 1 ¼, depending on type
Nominal diameters of pipe connections on suction side Rp 1, Rp 1 ¼ or Rp 1 ½, depending on type

Materials
Impellers of stainless steel 1.4301
Stage chambers made of 1.4301 stainless steel
Shaft of stainless steel 1.4301 (AISI 304) or 1.4057 (AISI 431 L)
EPDM seal
Housing cover EN-GJL-250 (KTL-coated)
Lower housing section EN-GJL-250 (KTL-coated)
Mechanical seal made of SiC/carbon
Bearing of tungsten carbide
Pump support foot EN-GJL-250 (KTL-coated)

Wilo Water Widget

Wilo-Water Widget Mechanically activated rainwater changeover device

Technical Data
• Maximum mains pressure: 1,050 kPa
• Maximum pump pressure: 1,050 kPa
• Maximum flow rate: 200 lpm
• Rainwater/mains water inlet: 1” BSP-F
• Outlets: 1” BSP-F
• Weight: 1.9 Kg

Features
• Easy to install
• Full flow 1” outlets
• Solid brass construction
• No electrical components
• No float switch required for automatic restarting of pumps
• Can be mounted in any position and any distance from the pump
• Certified dual check valve for backflow prevention
• Hydraulically operated

Wilo Water Widget

Wilo-Water Widget Mechanically activated rainwater changeover device

Technical Data
• Maximum mains pressure: 1,050 kPa
• Maximum pump pressure: 1,050 kPa
• Maximum flow rate: 200 lpm
• Rainwater/mains water inlet: 1” BSP-F
• Outlets: 1” BSP-F
• Weight: 1.9 Kg

Features
• Easy to install
• Full flow 1” outlets
• Solid brass construction
• No electrical components
• No float switch required for automatic restarting of pumps
• Can be mounted in any position and any distance from the pump
• Certified dual check valve for backflow prevention
• Hydraulically operated

Wilo Water Widget

Wilo-Water Widget Mechanically activated rainwater changeover device

Technical Data
• Maximum mains pressure: 1,050 kPa
• Maximum pump pressure: 1,050 kPa
• Maximum flow rate: 200 lpm
• Rainwater/mains water inlet: 1” BSP-F
• Outlets: 1” BSP-F
• Weight: 1.9 Kg

Features
• Easy to install
• Full flow 1” outlets
• Solid brass construction
• No electrical components
• No float switch required for automatic restarting of pumps
• Can be mounted in any position and any distance from the pump
• Certified dual check valve for backflow prevention
• Hydraulically operated

Wilo Fluid Control

pump controller
  • Plug & Play design for ease of installation and maintenance
  • Liquid-filled pressure gauge installed on side of controller (side-discharge version only)
  • Adjustable cut-in pressure setting 1.5-3 bar (side-discharge version only)
  • Protects pump against dry-running and enables automatic pressure control

Wilo Fluid Control

pump controller
  • Plug & Play design for ease of installation and maintenance
  • Liquid-filled pressure gauge installed on side of controller (side-discharge version only)
  • Adjustable cut-in pressure setting 1.5-3 bar (side-discharge version only)
  • Protects pump against dry-running and enables automatic pressure control
Call Us